Open data · CC-BY 4.0
Tesla Model 3 2170 cell dataset
Four cylindrical Tesla/Panasonic 2170 NCA cells from a Model 3 pack, tested at six temperatures with characterization tests and drive cycles generated by a validated Tesla Model 3 vehicle model. The open portion is yours to train on; the blind portion only ever runs inside the evaluator.
Four cells, four vehicle configurations
Each cell was cycled with a different vehicle configuration so the dataset covers payload and HVAC extremes.
| Cell | Payload | HVAC | Cycler channel | Role |
|---|---|---|---|---|
| m80 | 80 kg | On | Ch 1 | Open + blind cycles |
| m448 | 448 kg | On | Ch 2 | Blind, evaluation only |
| m448-N | 448 kg | Off | Ch 3 | Open + blind cycles |
| m1000 | 1000 kg | On | Ch 4 | Open + blind cycles |
Vehicle model: 1612 kg curb mass + payload, EPA road-load coefficients, 96s31p pack (2,976 cells, 50.4 kWh), 250 W accessory load, temperature-dependent HVAC power. Predicted EPA range 346 km vs 354 km official.
Test equipment
- Cycler: Arbin LBT, 8 × 60 A channels, ±2 mV / ±24 mA control accuracy
- Chamber: Envirotronics SH16C, 16 ft³, ±0.3 °C
- Sampling: resampled to 1 Hz
- Capacity at start: ≈ 4.7 Ah (4.5 Ah nominal)
- Chemistry: NCA (presumed)
Tests by Fauzia Khanum and Mina Naguib with Dr. Phillip Kollmeyer, McMaster University.
Open versus blind data
Every test runs at each of the six chamber temperatures, hottest first. Before every test the cell is returned to 25 °C and CC-CV charged to 4.2 V / 0.1 A so all tests start at 100 % SOC.
- -20 °C · coldest
- -10 °C · cold
- 0 °C · freezing
- 10 °C · cool
- 25 °C · room temperature
- 40 °C · hottest
| Test | m80 | m448 | m448-N | m1000 |
|---|---|---|---|---|
| C/20 discharge capacity (at 40 °C) | Open | Blind | Open | Open |
| C/3, C/2, 1C discharge | Open | Blind | Open | Open |
| C/20 charge and discharge | Open | Blind | Open | Open |
| HPPC (four pulse magnitudes) | Open | Blind | Open | Open |
| UDDS, HWFET (standard) · LA92, US06 (aggressive) | Blind | Blind | Blind | Blind |
| Eight reordered drive cycles | Open | Blind | Open | Open |
| HWCUST 1 / 2 (custom highway) | Open / Blind | Blind | Open / Blind | Open / Blind |
| HWGRADE 1 / 2 (highway with grade) | Open / Blind | Blind | Open / Blind | Open / Blind |
Drive cycles repeat until pack power capability (from HPPC, scaled to 2,976 cells) drops below 60 kW, the point a vehicle would enter a power-limited mode. At −20 °C this removes roughly a third of the usable capacity. Reference SOC uses the C/20 capacity measured at 40 °C before each temperature block, linearly interpolated across the tests in between.
File format
Every .mat file loads as a struct named meas with these columns.
| TimeStamp | MM/DD/YYYY HH:MM:SS AM |
| Time | s |
| Voltage | V, cell terminal |
| Current | A, negative = discharge |
| Ah | Ah counter (reset each test) |
| SOC | reference SOC from interpolated 40 °C capacity |
| Power | W |
| Wh | Wh counter |
| Battery_Temp_DegC | case temperature, mid-cell |
| Ambient_temp_degC | chamber set-point |
| Cycle_Label | e.g. UDDS |
| Test_Cell | e.g. m80 |
Files are named <order>_<test>_<date> Tesla_<temp>_<DriveCycles|Char>_Ch<n>.mat, e.g. 10_REORDERED1_11-08-21_15.03 Tesla_n10C_DriveCycles_Ch1.mat.
What's in the download
Download individual archives from Borealis.
- 5.6 MB
0-Documentation.zip
Submission guidelines, evaluation description, output-data reference, example-model walkthroughs and aiding-tool guides (five PDFs).
- 705 MB
1-Open Data.zip
All open characterization tests and drive cycles for m80, m448-N and m1000 at six temperatures, as MATLAB .mat structs (1 Hz).
- 10.4 MB
2-Aiding Tools.zip
Model Submission Test Tool, file Concatenation Tool and Figure Data Extraction Tool (MATLAB live scripts).
- 64.5 MB
3-Neural Network Training Example.zip
FNN and LSTM training scripts with instructions for extracting weights into a Model.m.
- 54 KB
4-SOC estimation Model Examples.zip
Four complete submission packages: coulomb counter, EKF, FNN and LSTM, the reference for the required format.
Known data notes (from the dataset README, v2, 2026-06)
- HWGRADE2 was identical to HWGRADE1 at 40 °C and 25 °C; it differs at the remaining temperatures.
- The −10 °C C/20 discharge/charge test and the −20 °C HPPC test were re-run after the characterization block; their timestamps differ.
- 2026-06-26: m1000 −20 °C standard cycles and HWCUST2/HWGRADE2 moved from open to blind for consistency with the paper; two missing m80 25 °C characterization files were added.
Use of the data requires citing the ITEC 2022 paper and the Borealis dataset; see the methodology page.