Skip to main content

Open data · CC-BY 4.0

Tesla Model 3 2170 cell dataset

Four cylindrical Tesla/Panasonic 2170 NCA cells from a Model 3 pack, tested at six temperatures with characterization tests and drive cycles generated by a validated Tesla Model 3 vehicle model. The open portion is yours to train on; the blind portion only ever runs inside the evaluator.

Four cells, four vehicle configurations

Each cell was cycled with a different vehicle configuration so the dataset covers payload and HVAC extremes.

CellPayloadHVACCycler channelRole
m8080 kgOnCh 1Open + blind cycles
m448448 kgOnCh 2Blind, evaluation only
m448-N448 kgOffCh 3Open + blind cycles
m10001000 kgOnCh 4Open + blind cycles

Vehicle model: 1612 kg curb mass + payload, EPA road-load coefficients, 96s31p pack (2,976 cells, 50.4 kWh), 250 W accessory load, temperature-dependent HVAC power. Predicted EPA range 346 km vs 354 km official.

Test equipment

  • Cycler: Arbin LBT, 8 × 60 A channels, ±2 mV / ±24 mA control accuracy
  • Chamber: Envirotronics SH16C, 16 ft³, ±0.3 °C
  • Sampling: resampled to 1 Hz
  • Capacity at start: ≈ 4.7 Ah (4.5 Ah nominal)
  • Chemistry: NCA (presumed)

Tests by Fauzia Khanum and Mina Naguib with Dr. Phillip Kollmeyer, McMaster University.

Open versus blind data

Every test runs at each of the six chamber temperatures, hottest first. Before every test the cell is returned to 25 °C and CC-CV charged to 4.2 V / 0.1 A so all tests start at 100 % SOC.

  • -20 °C · coldest
  • -10 °C · cold
  • 0 °C · freezing
  • 10 °C · cool
  • 25 °C · room temperature
  • 40 °C · hottest
Testm80m448m448-Nm1000
C/20 discharge capacity (at 40 °C)OpenBlindOpenOpen
C/3, C/2, 1C dischargeOpenBlindOpenOpen
C/20 charge and dischargeOpenBlindOpenOpen
HPPC (four pulse magnitudes)OpenBlindOpenOpen
UDDS, HWFET (standard) · LA92, US06 (aggressive)BlindBlindBlindBlind
Eight reordered drive cyclesOpenBlindOpenOpen
HWCUST 1 / 2 (custom highway)Open / BlindBlindOpen / BlindOpen / Blind
HWGRADE 1 / 2 (highway with grade)Open / BlindBlindOpen / BlindOpen / Blind

Drive cycles repeat until pack power capability (from HPPC, scaled to 2,976 cells) drops below 60 kW, the point a vehicle would enter a power-limited mode. At −20 °C this removes roughly a third of the usable capacity. Reference SOC uses the C/20 capacity measured at 40 °C before each temperature block, linearly interpolated across the tests in between.

File format

Every .mat file loads as a struct named meas with these columns.

TimeStampMM/DD/YYYY HH:MM:SS AM
Times
VoltageV, cell terminal
CurrentA, negative = discharge
AhAh counter (reset each test)
SOCreference SOC from interpolated 40 °C capacity
PowerW
WhWh counter
Battery_Temp_DegCcase temperature, mid-cell
Ambient_temp_degCchamber set-point
Cycle_Labele.g. UDDS
Test_Celle.g. m80

Files are named <order>_<test>_<date> Tesla_<temp>_<DriveCycles|Char>_Ch<n>.mat, e.g. 10_REORDERED1_11-08-21_15.03 Tesla_n10C_DriveCycles_Ch1.mat.

What's in the download

Download individual archives from Borealis.

  • 0-Documentation.zip

    Submission guidelines, evaluation description, output-data reference, example-model walkthroughs and aiding-tool guides (five PDFs).

    5.6 MB
  • 1-Open Data.zip

    All open characterization tests and drive cycles for m80, m448-N and m1000 at six temperatures, as MATLAB .mat structs (1 Hz).

    705 MB
  • 2-Aiding Tools.zip

    Model Submission Test Tool, file Concatenation Tool and Figure Data Extraction Tool (MATLAB live scripts).

    10.4 MB
  • 3-Neural Network Training Example.zip

    FNN and LSTM training scripts with instructions for extracting weights into a Model.m.

    64.5 MB
  • 4-SOC estimation Model Examples.zip

    Four complete submission packages: coulomb counter, EKF, FNN and LSTM, the reference for the required format.

    54 KB

Known data notes (from the dataset README, v2, 2026-06)

  • HWGRADE2 was identical to HWGRADE1 at 40 °C and 25 °C; it differs at the remaining temperatures.
  • The −10 °C C/20 discharge/charge test and the −20 °C HPPC test were re-run after the characterization block; their timestamps differ.
  • 2026-06-26: m1000 −20 °C standard cycles and HWCUST2/HWGRADE2 moved from open to blind for consistency with the paper; two missing m80 25 °C characterization files were added.

Use of the data requires citing the ITEC 2022 paper and the Borealis dataset; see the methodology page.